ICE Product Catalog 2026

BEAM COMBINED WALLS

AVAILABLE STEEL GRADES

AMERICAN

CANADIAN

YIELD STRENGTH

YIELD STRENGTH

ASTM

WF

NZ & PZ

CSA G40.21

WF

NZ & PZ

ksi

ksi

MPa

MPa

Grade 350 W 50

A36

36

250

350

A572

50-65

345-450

✔ ✔

A588

50

345

✔ ✔

A690

50

345

✔ ✔

A709

50

345

A913

50-80*

345-550

A992

50

345

* Inquire for availability.

Additional grades available upon request.

DELIVERY CONDITIONS & TOLERANCES

SHEET PILE

ASTM A6

EN10248

Mass

± 2.5%

± 5%

Length

+ 5 in.

± 200 mm

Height

± 7 mm

≤ 8.5 mm > 8.5 mm

Thickness

Width

± 2%

± 3%

Double Pile Width

0.2% of the length

Straightness

2% of the width

Ends out of Square

WIDE FLANGE BEAMS

ASTM A6

Mass

± 2.5%

Depth

± 0.125 in.

Length

30 ft. and under

Over 30 ft.

Beams W24 and Under

± 0.375 in.

+ ( 0.375 in. + (Length - 30) / 80 -0.375 in.

Beams Over W24

± 0.5 in.

+ ( 0.5 in. + (Length - 30) / 80 -0.375 in.

Flanges out of Square Beams W12 and Under

≤ 0.25 in.

Beams Over W12

≤ 0.3125 in.

Web off Center

≤ 0.1875 in.

Greatest Depth over Theoretical

≤ 0.25 in.

Camber and Sweep

(0.125 in) * (Length / 10)

Camber and Sweep for Columns** 45 ft. and Under

(0.125 in) * (Length / 10) but not over 0.375 in.

Over 45 ft.

(0.375 in) + (0.125 in * (Length - 45) / 10

** W8 x 31 and heavier, W10 x 49 and heavier, W12 x 65 and heavier, and W14 x 90 and heavier; order as columns. If other sections are ordered as columns, the tolerances are subject to negotiation with the manufacturer.

Technical Hotline: 866.875.9546 | engineering@nucorskyline.com | www.nucorskyline.com 22