ICE Product Catalog 2026

PIPE COMBINED WALLS

SAMPLE CALCULATION

54” x 0.563” Pipe with 5 in. NZ 19 Flanges & NZ 19

NZ 19 Width = 27.56 in. Inertia = 283.1 in 4 /ft See page 5 for details

54 in x 0 563 in Inertia = 33,740 in 4 /ft See page 25 for pipe properties

NZ 19 Flanges Width = 5 in.

System Width b sys = 119.1 in.

b sys

= 54 in + 2*(5 in + 27.56 in) = 1191 in

= (π/64)(OD 4 – ID 4 ) = (3.14/64)((54 in) 4 – (54 in – 2*0.563 in) 4 = 33,739.81 in 4 = 2 * b sys * I sp /ft = (2 * 27.56 in * 283.1 in 4 /ft) / 12 in/ft 1,300 in 4

I pipe

A

A

I sp

Sheet Pile

Pipe Pile

Properties through A-A I sys = (I pipe + I sp ) / b sys

= (33,739.81 in 4 + 1,300 in 4 ) / (119.1 in / 12 in/ft) 3,530 in 4 /ft

B

B

= I sys / (OD/2)

S sys

3,530 in 4 /ft / (54 in / 2) 1307 in 3 /ft

Properties through B-B I sys = (33,739.81 in

4 ) / (119.1 in / 12 in/ft)

3,399 in 4 /ft

=

= 3,399 in

4 /ft / (54 in / 2)

S sys

1259 in 3 /ft

Technical Hotline: 866.875.9546 | engineering@nucorskyline.com | www.nucorskyline.com 17

Made with FlippingBook - professional solution for displaying marketing and sales documents online