ICE Product Catalog 2024

THE MULTIPURPOSE PILING RIG / TECHNOLOGIES | 03

TECHNOLOGIES

The unique design of the CH 450 adapts to a wide range of drilling technologies that include:

KP - Uncased Kelly Piles excavated by dry method or stabilized by fluid overpressure CKP - Kelly Piles with Casing installation by rotary drive or optionally by hydraulic casing oscillator m.s. i.s. KP CKP Max. pile diameter CPD mm ft-in 2.000 1 6’ 7” 1 1.500 3/4

KP (Kelly Piles)

4’ 11” 3/4 4’ 3” 3/4 185’ 8” 5 206’ 4” 2

Max. pile diameter WPD Max. pile depth CPD Max. pile depth WPD Pile diam with casing oscillator min.-max.

mm mm mm

2.000 1 56.600 2 62.900 2

ft-in ft-in ft-in

6’ 7” 1

1.300 3/4 56.600 5 62.900 2

185’ 8” 2 206’ 4” 2

CKP (Cased Kelly Piles)

1’ 11” - 3’ 11”

mm

600 - 1.200

ft-in

NOTES 1 - Tool below mast

2 - Using self mounting kelly bar 3 - Depending on the twister

4 - Standard drilling axis 5 - Open hole (uncased) depth

CFA - Piles that are drilled uncased by the use of a continuous hollow auger stem m.s. i.s. CFA Max. pile diameter mm ft-in 1.000 3’ 3” Max. pile depth (CFA/WPD) mm ft-in 14.000 + 7.000 = 21.000

CFA (Continuous Flight Auger)

45’ 11” + 22’ 11” = 68’ 10” 54’ 2” + 19’ 8” = 73’ 10” 59’ 1” + 19’ 8” = 78’ 9” 62’ 4”+19’ 8” = 81’ 12”

Max. pile depth (CFA T4) Max. pile depth (CFA T4 XL)

mm mm

ft-in 16.500 + 6.000 = 22.500 ft-in 18.000 + 6.000 = 24.000 ft-in 19.000 + 6.000 = 25.000

Max. pile depth (CFA T4 XXL) mm

DP - Piles installed without soil removal by advancing a special tool into the ground that causes the soil to be displaced radially and vertically m.s. i.s. DP Max. pile diameter mm ft-in 450 1’ 5” Max. pile depth mm ft-in 13.500 + 8.500 = 22.000 44’ 3”+ 27’ 11”= 72’ 2” SM - Piles constructed by mixing and partly replacing the existing soils with grout using a soil mixing tool m.s. i.s. SM Pile diameter mm ft-in 400 - 2.000 4 1’ 4” - 6’ 7” 4 Max. pile depth mm ft-in 13.500 + 8.500 = 22.000 44’ 3”+ 27’ 11”= 72’ 2”

DP (Displacement Piles)

SM (Soil Mixing)

NOTES 4 - According to the soil conditions

LDTH - Piles installed with DTH method using bits of a larger diameter than standard bits m.s. i.s. LDTH Max. pile diameter mm ft-in 1.000 3’ 3” Max. pile depth mm ft-in Approx. 50.000 - 60.000 5 164’ - 196’ 5

LDTH (Large DTH)

NOTES 5 - Max. depth is upon drill string weight

MP - Installed using conventional air-flush rotary drilling m.s. i.s.

MP

MP (Micropiles)

Max. pile diameter Stroke of rotary head

mm mm

610

ft-in ft-in

24’

14.500

47’ 6”

The CH 450 can be offered in different LHR (ow head room) configurations, designed for the construction of bored piles in challenging access sites.

Made with FlippingBook - professional solution for displaying marketing and sales documents online